NOUTATI

Jan 172010
 


DESCRIERE

  • Pereti de compartimentare(DESCRIERE CA LA CARTE)

    Tip de constructie LG 39
    LB POS Nr.
    Cod Imbracaminte Grosime perete mm Protectie antifoc Izolare fonica Izolare termica Greutate perete KG/mp Inaltime maxima a peretilor in mm
    Domeniul de aplicare
    Rw (dB) Dn, T, w D (mpK/W) K (W/mpK) I H
    Pereti cu un singur rand de montanti metalici
    3.40.01a fara fibre minerale CW 50/80 2 RF 15 80 F 30 41 38 ca. 30 3000
    3.40.01b cu fibre minerale 39.01.01 A CW 50/80 2 RB 15 80 45 38 1.14 0.72 ca. 30 3000
    39.01.02 A CW 50/80 2 RF 15 80 F 30 45 38 1.14 0.72 ca. 30 3000
    3.40.02 39.01.01 B CW 75/100 2 RB 12.5 100 50 44 1.12 0.73 ca. 25 3750 3250
    39.01.01 C CW 75/105 2 RB 15 105 50 44 1.14 0.72 ca. 30 4000 3500
    39.01.02 B CW 75/100 2 RF 12.5 100 F 30 50 44 1.12 0.73 ca. 25 3750 3250
    39.01.02 C CW 75/105 2 RF 15 105 F 30 50 44 1.14 0.72 ca. 30 4000 3100
    3.40.03 39.01.01 D CW 100/125 2 RB 12.5 125 50 44 1.12 0.73 ca. 25 4500 4000
    CW 100/130 2 RB 15 130 50 44 1.14 0.72 ca. 30 4500 4000
    39.01.02 D CW 100/125 2 RF 12.5 125 F 30 50 44 1.12 0.73 ca. 25 4500 4000
    CW 100/130 2 RF 15 130 F 30 50 44 1.14 0.72 ca. 30 4500 4000
    3.40.04 39.01.01 E CW 50/100 4 RB 12.5 100 52 48 1.24 0.67 ca. 50 3250 2750
    39.01.02 E CW 50/100 4 RF 12.5 100 F60 52 48 1.24 0.67 ca. 50 3250 2750
    39.01.03 A CW 50/100 4 RF 12.5 100 F 90 52 48 1.24 0.67 ca. 50 3250 2750
    3.40.05 39.01.01 F CW 75/125 4 RB 12.5 125 53 48 1.24 0.67 ca. 50 4250 3750
    39.01.02 F CW 75/125 4 RF 12.5 125 F60 53 48 1.24 0.67 ca. 50 4250 3750
    39.01.09 B CW 75/125 4 RF 12.5 125 F 90 53 48 1.24 0.67 ca. 50 4250 3750
    3.40.06 39.01.01 G CW 100/150 4 RB 12.5 150 55 50 1.24 0.67 ca. 50 5000 4500
    39.01.02 G CW 100/150 4 RF 12.5 150 F60 55 50 1.24 0.67 ca. 50 5000 4500
    39.01.03 C CW 100/150 4 RF 12.5 150 F 90 55 50 1.24 0.67 ca. 50 5000 4500
    3.40.10 CW 75/150 6 RB 12.5 150 57 55 1.36 0.62 ca. 75 5000 5000
    CW 100/175 6 RF 12.5 175 (max. 180) 57 55 1.36 0.62 ca. 75 7500 7500
    CW 125/200 6 RF 12.5 200 F 90 57 55 1.36 0.62 ca. 75 max. 9000
  • Pereti de compartimentare

    Tip de constructie LG 39
    LB POS Nr.
    Cod Imbracaminte Grosime perete mm Protectie antifoc Izolare fonica Izolare termica Greutate perete KG/mp Inaltime maxima a peretilor in mm
    Domeniul de aplicare
    Rw (dB) Dn, T, w D (mpK/W) K (W/mpK) I H
    Pereti cu doua randuri de montanti metalici
    3.41.01 39.01.04 A CW 50+50/155 4 RB 12.5 156 61 55 1.24 0.67 ca. 55 3000 2500
    39.01.05 A CW 50+50/156 4 RF 12.5 156 F90 61 55 1.24 0.67 ca. 55 3000 2500
    1) CW 50+50/… 2600
    3.41.02 39.01.04 B CW 75+75/205 4 RB 12.5 205 63 55 2.24 0.45 ca. 55 4000 3500
    39.01.05 B CW 75+75/205 4 RF 12.5 205 F90 63 55 2.24 0.45 ca. 55 4000 3500
    CW 75+75/… 3500 2600
    3.41.03 39.01.04 C CW 100+100/255 4 RB 12.5 255 65 55 1.24 0.67 ca. 55 4500 4000
    39.01.05 C CW 100+100/255 4 RF 12.5 255 F90 65 55 1.24 0.67 ca. 55 4500 4000
    1) CW 100+100/… 4 RB 12.5 4000 3500
    3.41.20 39.01.06 C CW **** 5 RF 12.5 220 F90 62 55 2.30 0.41 ca. 60 4250 3750
    39.01.06 C CW **** 5 RF 12.5 220 F90 62 55 2.30 0.41 ca. 60 4250 3750
    * Prescriptiile privind izolarea zgomotelor aeriene dintre incaperi (ONORM B 8115, partea a doua, tabel 5) sunt stabilite si Dn, T, w (diferente de nivel evaluate pentru zgomote normale). Pentru ca peretii despartitori sa indeplineasca aceste cerinte, trebuie sa aiba “un indicator evaluat al izolarii zgomotelor” Rw, a carui valoare numerica sa fie mai mare decat valoarea numerica a cerintei din Dn, T, w. Transmisia sunetelor prin cele patru parti structurale alaturate este de luat in consideratie in mod suplimentar prin respectarea conditiilor de transmisie longitudinala a zgomotelor (vezi “Izolarea acustica”).
  • Pereti de compartimentare

    Tip de constructie Numarul tavanului de montaj RIGIPS Placi RIGIPS Protectie antifoc
    clasa rezistentei la foc
    4.10.01Plafon fix cu structura din lemn
    2 straturi
    caroiaj primar 60/40mm sipci lemn
    caroiaj primar 40/60mm sipci lemn
    caroiaj sipci 50/30mm sau 48/24mm
    dispozitiv agatare-ancora rapid
    x=750mm
    y=850mm
    l=400mm
    39.08.01 A RB 12.5
    39.08.01 B RB 15
    39.08.01 C RF 12.5
    39.08.01 D 2 RF 12.5 F30 (*)
    39.08.01 E RF 15
    39.08.01 F 2 RF 15 F60 (**)
    4.10.01Plafon suspendat cu structura din lemn
    2 straturi
    intervale de fixare a infrastructurii tavanului:
    x 750mm la sipci 50/30mm
    y 850mm la sipci 60/40mm
    y 850mm la sipci 40/60mm
    y 750mm la profilele C60/27mm
    l 400mm
    39.08.04 A RB 12.5
    39.08.04 B RBI 12.5
    39.08.04 C RF 12.5
    39.08.04 D RB
    39.08.04 E 2 RF 12.5 F30 (*)
    39.08.04 E 2 RF 15 F60 (**)
    4.10.01Plafon suspendat cu structura metalica
    2 straturi
    intervale de fixare a infrastructurii tavanului:
    x 850mm
    y 750mm, la profilele C60/27mm
    l 350mm
    39.08.03 A RB 12.5
    39.08.03 B RBI 12.5
    39.08.03 C RF 12.5
    39.08.03 D RB
    39.08.03 E 2 RF 12.5 F30 (*)
    39.08.03 E 2 RF 15 F60 (**)
    4.10.01Plafon suspendat cu structura metalica
    3 straturi
    intervale de fixare a infrastructurii tavanului:
    x 600mm
    y 750mm
    l 400mm
    profile CD 60/27mm
    39.08.03 E39.08.13 E 2 RF 15+1 RF 12.5 F90Testarea protectiei anti-foc DIN 4102

    De la fata inferioara a celor doua placi RIGIPS (una RF 15mm + una RF 12.5 + una RF 15mm) pana la fata superioara a paturii izolante

    (*) De la fata inferioara a celor doua placi anti-foc RIGIPS de 12.5mm grosime (doua RF 12.5mm), pana la fata superioara a placilor anti-foc RIGIPS
    (**) De la fata inferioara a celor doua placi anti-foc RIGIPS de 12.5mm grosime (unu RF 12.5mm), pana la fata superioara a planseului de lemn

  • Plafoane fixe si suspendate

    Tip de constructie Numarul tavanului de montaj RIGIPS Placi RIGIPS Protectie antifoc
    clasa rezistentei la foc
    4.30.04Plafon suspendat cu structura metalica
    prindere de planseu beton armat
    x 1000mm
    y 900mm
    l 400mm
    39.08.03 C RF 12.5 F60De la fata inferioara placii de 12.5mm anti-foc RIGIPS (RK 12.5mm) pana la fata superioara a planseului de beton armat
    39.08.03 E RF 15 F90De la fata inferioara placii de 15mm anti-foc RIGIPS (RK 15mm) pana la fata superioara a planseului de beton armat
    4.40.01Plafon suspendat cu structura metalica
    cu vata minerala
    clasa A de combustibilitate
    prindere de planseu din tabla
    profilat trapezoidal
    cu suprabetonare armata 50mm
    x 850mm
    y ca. 500mm
    l 400mm
    39.08.01 E RF 15 F90De la fata inferioara placii de 15mm anti-foc RIGIPS (RFK 15mm) pana la fata superioara a suprabetonarii
    39.08.13 E Material izolant
    4.50.01Plafon fix cu structura din lemn
    cu izolatie 2x40mm
    saltele din vata minerala
    si cu placi RIGIPS rezistente la foc
    x 850mm
    y 1000mm la sipci 60/40mm
    l 400mm
    39.08.01 C RF 12.5 F30De la fata inferioara placii de 15mm anti-foc RIGIPS (RK 15mm) pana la fata superioara a placilor de spuma rigida
    39.08.13 E Material izolant
    4.50.02Plafon fix cu structura din lemn
    prindere de grinzi metalice
    cu izolatie 2×30
    saltele din vata minerala
    cu placi RIGIPS rezistente la foc
    x 850mm
    y 1000mm
    l 400mm
    39.08.01 C RF 12.5 F30De la fata inferioara placii de 15mm anti-foc RIGIPS (RK 15mm) pana la fata superioara a placilor de spuma rigida
Rate this post